82
Standard 2 of 5
Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Check-sum verification: The checksum is made as the sum
module 10 of the numerical values of all data digits.
Check-sum transmission: By setting Enable, checksum
will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code ID setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to page 36
Insertion group number selection of UPCA.
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00
01
Check-sum
verification
Disable
Enable
00
01
Program