GetBacklightStatus
This function gets screen backlight status.
DWORD GetBacklightStatus
{
}
Parameters
None.
Return Values
The return value indicates whether screen backlight is 1 = screen backlight on or screen backlight is 0 = screen
backlight off.
Example
DWORD dwResult;
dwResult = GetBacklightStatus();
if(dwResult == 1)
AfxMessageBox(_T("Backlight on"));
else
AfxMessageBox(_T("Backlight off"));
Requirements
OS Versions: Windows CE 5.0 and later.
Header: sysapiax.h
Link Library: sysapiax.lib
Link DLL: sysapiax.dll
Device: PT60