1 Product Engineering Specification – Scan Utility Overview: 1. What is Scan Utility? Scan Utility provides a user interface that communicates wit
10 Case conversion: For the barcode, you can set the alphabet in either upper case or lower case. 7. String Settings Prefix characters: U
11
12 8. DataMagic DataMagic only supports the newest Argox scanner models, such as the AR-3000 and the AI-6800. The scanners allow a maximum of 10 Ru
14
15
16
17 Step 1: Set up string groups In the Scanner Setup / String setting screen below, set the content to insert: Insert G1: 49 Insert G2: AA Insert
18 Step 2: Set up DataMagic In the Scanner Setup / DataMagic screen, set the Rules as below: Rule 1: Replace G1 (49) with G2 (AA) Rule 2: Insert F
19 Step 3: In the Linear Barcode setup / EAN screen, enable DataMagic for EAN-13.
2 File 1. New: Open a new project. All of the settings are set to default depending on the scanner model. 2. Open: Open an existing file.
20 Step 4: In the Scanner Setup / Interface Selection screen, select the interface and Com port.
21 Step 5: In the Scanner Utility / Tool menu, select “Export Config from Host” and then the device.
22 Linear Barcodes Setup 1. Symbologies Symbology: You must select barcode type before setting the parameters. Note: You
23 Truncate leading/ending: The leading or ending digits of barcode data characters can be truncated when these values are set to non-zero. This will
24 3. Code93 Checksum Verification: The checksum is made as the sum module 47 of the numerical values of all data digits. Checksum
25 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of Code-39. Code Id
26 Datamagic: By setting Enable to run this function. Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leadin
27 Supplement digits: Format: EAN-8 Format: EAN-13 Truncate Leading zero: Refer to
28 Max./Min. code length: Refer to Max./Min. code length of Code-39. Truncate leading/ending: Refer to Truncate leading/ending of Code-39. Code Id
29 Insertion group selection: Refer to Insertion group selection of Code-39. 9. Others Read (Telepen): IATA (International Air Transport Assoc
3 Toolbar Icon definitions starting from left are: 1. Open a new project 2. Open 3. Save a file 4. Setup RS-232 5. Export parameters to Sca
30 10. UPC Check-sum transmission: By setting Enable, checksum is transmitted. Datamagic: By setting Enable to r
31 11. Matrix 25 Eur Checksum Verification: The checksum is made as the sum module 10 of the numerical values of all data digits.
32
33 Barcode in 2D Setup 1. Symbologies Symbologies: You have to select barcode type before setting the parameters. 2. PDF-417 Only the AS-8250/
34 3. Code-16K Only the AS-8250/8312/9500 can decode Code-16K. Truncate leading/ending: Refer to Truncate leading/ending of Code-39. Code Id set
35 Downloading 1. Host RS-232 Setup Setup the output port and protocol of host. Port Baud Rate Data Bits Parity Stop Bits Flow Control
36 AR-3000 Baud rate default is 115200BPS. Data Export (Host -> Scanner) Export the default value from Scan Utility to Scanner.
37 Download Firmware ASCII Code Table L H 2 3 4 5 6 7 0 SP 0 @ P ` p 1 ! 1 A Q a q 2 “ 2 B R b r 3 # 3 C S c s 4 $ 4 D T d t 5 % 5 E
4 Scanner Setup 1. Interface Selection Settings Interface Selection: You can change the factory interface default for another interface. By pluggi
5 match your host keyboard speed. Function Key: Set Enable and the scanner can output code by pressing a function key in your application program
6 None - Communication only uses T×D and R×D signals without regard for any hardware or software handshaking protocol. RTS/CTS - If the scanner wan
7 4. Wand Emulation Settings Bar/space polarity: High/low - Black is transmitted as a high voltage level (+5) and space as low level (0V).
8 5. Parameter Settings for Indication and Transmission Power on alert: After power-on the scanner will generate an alert signal to indicate a suc
9 6. Parameter Settings for Scanner Preamble transmission: Set to Enable to append the Preamble before the transmitted data. Postamble tr