PT-Basic Programming Manual Ver. 1.00 49/143
SIM_SCANKEY_PRESS
Purpose
To simulator the Scan key press or release.
Syntax
SIM_SCANKEY_PRESS(N1%)
Example
Set the scan key pressed.
SIM_SCANKEY_PRESS(1)
Set the scan key released.
SIM_SCANKEY_PRESS(0)
Description
This command can simulator the scan key status for pressed
or released.
READER_SETFROMFILE
Purpose
To set scanner setting by scanner setting file.
Syntax
A%=READER_SETFROMFILE(FilePath$)
Example
A%=READER_SETFROMFILE("c:\data\PA21.axs")
Description
A% is an integer variable to be assigned to the result.
A%
Meaning
0
Setting fail
1
Setting OK
FilePath $ is a string variable, indicating the Scanner setting
file path.