Argox PA-20 Basic Programming Manual Manual de usuario Pagina 94

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 143
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 93
PT-Basic Programming Manual Ver. 1.00 93/143
FILE_TRANS_BAUD
Purpose
To get or set the transmission baud rate.
Syntax
A% = FILE_TRANS_BAUD
FILE_TRANS_BAUD = X%
Example
N%=FILE_TRANS_BAUD
FILE_TRANS_BAUD=2 „baud rate is 38400 bps
Description
A% is an integer variable to be assigned for the transmission
baud rate.
X% is an integer variable indicating baud rate to be set.
FILE_TRANS_BAUD
Baud rate (bps)
0
115200
1
57600
2
38400
3
19200
4
9600
5
4800
FILE_TRANS_INTERFACE
Purpose
To get or set the transmission interface.
Syntax
A% = FILE_TRANS_INTERFACE
FILE_TRANS_INTERFACE = X%
Example
N%=FILE_TRANS_INTERFACE
FILE_TRANS_INTERFACE=0 „RS-232
Description
A% is an integer variable to be assigned for the transmission
interface.
X% is an integer variable indicating interface to be set.
FILE_TRANS_INTERFACE
Interface
0
RS-232
1
USB